Interface Modules

 

 

Below are a list of the interface modules available. All these modules are designed to be used with the Fieldbus P-NET (refer to Fieldbus). The modules provide the ability to interface with almost any process sensor or control, providing the means of distributing control/intelligence. The modules can be supplied as separate units for customers to build their own system or will be used by us to provide a complete system to suit our customers requirements.

Also detailed below are the communication modules, which provide the ability to connect a P.C. using VIGO to the P-NET or a RS232 devices to P-NET.

To obtain further information on any of the modules below, please use the Information request Form below.

Interface Modules: ( follow link to see more detail on individual modules)

 

PD3100 Digital I/O DC Interface:    32 Input/Output Channels, which can be connected 

                                                       directly to 24 VDC equipment.

 

PD3120 Digital I/O DC Interface:    16 Input/Output Channels for 24 VDC, also includes an 

                                                        internal user programmable calculator channel for local 

                                                        control.

 

PD3150 Digital I/O DC Matrix:    32 Input/Output Channels, which can be connected directly 

                                                    to 24 VDC equipment. 16 off Sink and 16 off Source making 

                                                    module suitable for matrix connections.

 

PD3221 Universal Process Interface:     6 Digital Input Channels (4 off Input/Output), 2 

                                                             Analogue Inputs (current/voltage/PT-100), 1 Analogue 

                                                             Output. Also includes calculator, pulse processor and 

                                                              PID channels.  

 

PD3230 Weight Transmitter:        1 High resolution weight input channel (suitable for paralleling  

                                                    up to 10 x 600 Ohm Standard load cells. 6 Digital Input 

                                                    Channels (4 off Input/Output) and Calculator channel. Can be 

                                                    used to perform Belt Weight functions. 

                                                    PD3235 also available for use with up to 10 x 300 Ohm load 

                                                    cells.

 

PD3234 Weight Transmitter:        1 High resolution weight input channel (suitable for paralleling  

                                                    up to 10 x 600 Ohm Semiconductor load cells. 6 Digital 

                                                    Input Channels (4 off Input/Output) and Calculator channel. 

                                                    Can be used to perform Belt Weight functions.

 

 PD3240 Analogue Interface:        16 analogue Input channels ( 0-20 & 4-20mA) provides the 

                                                     ability to convert measurement directly into Engineering Units.

 

PD3250 Analogue Interface:        16 analogue Input channels for voltage ( 0-100mV or 

                                                    Thermocouple inputs) and 1 PT-100 Input. The module also 

                                                    provides the ability to convert voltage measurement directly 

                                                    into Engineering Units.

 

PD3260 Power Monitor:             1 Power Monitor channel, 1 Generator Switch, 1 Thyristor 

                                                   Switch and 8 Digital Input/Outputs also includes an internal      

                                                   user programmable calculator channel for local control.

 

PD3280 P-NET Repeater:          3  RS485 P-NET Interfaces , used to provide galvanically

                                                   isolated extension between P-NET sections, making

                                                   addressing of modules between sections transparent.

 

PD3285 P-NET Repeater:          3  RS485 P-NET Interfaces , used to provide galvanically

                                                   isolated extension between P-NET sections, making

                                                   addressing of modules between sections transparent. Also 

                                                   provides 1 interface for duplex optical fibre capable of 

                                                   extending the P-NET up to 3.1km.

 

PD3940 RS232/P-NET:           module providing communication between P-NET and RS232 devices such as printers 

                                                 barcode readers.

 

Communication Modules( follow link to see more detail on individual modules)

 

PD3920 PC/P-NET Interface:    ISA half size expansion board, allowing PC to connect to 

                                                  P-NET Fieldbus.

 

PD3930 Parallel PC/P-NET:     module providing ability to connect PC to P-NET Fieldbus via 

                                                   PC Parallel Port.

 

 

 

 

  


Module Information Request Form

Select the items that apply, and then let us know how to contact you.

Send Interface Module literature
Send Literature on Full Range of Company Products
Have a salesperson contact me

Name
Title
Company
Address
E-mail
Fax 
Phone

 

 

Home ] Up ] PD3150. ] PD3234. ] PD3240. ] PD3280. ] PD3260. ] PD3940. ] PD3930. ] PD3920. ] PD3250. ] PD3230. ] PD3221. ] PD3120. ]

Send mail to webmaster@calm-controls.co.uk with questions or comments about this web site.
Last modified: June 25, 2008